Menu
ANEST IWATA
Painting Machine
ANEST IWATA CYP-A1, A4 cylinder pump unit
ANEST IWATA Constant Volume Fluid Supply Pump Unit.
ANEST IWATA CYP-A1, A4 cylinder pump unit.
Adjustment-Free Supply System Cylinder Pump Unit. This convenient constant volume supply pump unit eliminates the need for measurement.

Effects of the Stable Paint Supply on the Paint Surface

●The flow rate can be changed easily with the touch input feature.
 The flow rate is not influenced by changes in the conditions such as paint property, paint viscosity, and path clogging.
 It is no longer necessary to perform the burdensome task of flow rate adjustment.
●The flow rate can be set in the range of 1 to 860 mL/minute.
●Discharge accuracy: ±0.1%
●Supports paint viscosities of up to 35 seconds/NK-2.
●The pressure controller prevents excessive initial paint output.


Effects of the Stable Paint Supply on the Paint Surface


Area of Compatibility by Paint Type
 The cylinder pump can always provide a stable paint supply regardless of temperature change,
 thixotropic change, viscosity change, path clogging, etc.


Area of Compatibility by Paint Supply Method
 The cylinder pump can provide a paint supply with higher repeated accuracy than the other paint supply methods.

  Driving selection
Model The number of cylinders to be mounted Driving
system
Effective
stroke
Type
of
driving
resolution Output
speed
Dimensions
mm
(L×W×H)
Mass
kg
CYP-A1
(For 1 gun)
CYP-A4
(For 2-4 gun)
CYP-A1
1
CYP-A4
2-4
AC
serve
motor
120mm Feeding by ball screw 0.0010306
mℓ/pls
Max
860mℓ/min
400×255×610 15


Cylinder piston ASSY
Model Effective
cylinder capacity
Material of cylinder Material of piston pin Piston
ring
CYP-P1 100mℓ SUS304 SUS304 O-ring


Controller
Model Display Air output Alarm Singal electric source Working temperature range Dimensions
mm
(L×W×H)
Mass
kg
CYP-C1 Touch
panel
CCV side:
4 types
Spray gun side:1 type
11
types
Input:
9
Output:
8
AC200V±10%
single
phase
0 〜 40℃ 
non-condensing
300×250×500 about
8
Safety function : Motor stop by detecting servo motor load
Automatic mode:Automatic discharge and automatic filling by external command
Manual mode:Filling, flushing, JOG (inching), valve operation
Control function:Pressure adjustment, cylinder selection, setting conditon of piston operation
adjustment for counter fill and discharge speed.