Menu
"Statiller 20S, 30S"
Shishido direct current high-voltage generators Statiller 20S and Statiller 35S.
As a power supply unit in experiments related to static electricity.
Shishido electrostatic, ltd., ESD solutions and productions.
Direct current high-voltage generators.
STATILLER 35S, 20S.

The STATILLER devices are most suited to use as a power supply unit in experiments related to static electricity,
and for devices requiring the application of static electricity.
In addition to the standard products available,
Our company can also design and manufacture a device in accordance with any special specifications required to suit the desired purpose of use.
Please contact your sales representative for further details.

●Model name and power supply cable:
Type Model Power supply cable
STATILLER 20S 100V~240V, - polarity 20S1-01 2-Pin cable
STATILLER 20S 100V~240V, + polarity 20S1-02
STATILLER 35S 100V , - polarity 35S3-100-N-1
STATILLER 35S 100V , + polarity 35S3-100-P-1
STATILLER 35S 200V , - polarity 35S3-200-N-1 Open-end
STATILLER 35S 200V , + polarity 35S3-200-P-1
STATILLER 35S 220V , - polarity 35S3-220-N-1
STATILLER 35S 220V , + polarity 35S3-220-P-1
STATILLER 35S 240V , - polarity 35S3-240-N-1
STATILLER 35S 240V , + polarity 35S3-240-P-1


●Explanation of Model names STATILLERS:
 Example: 35S3-A-B-C :

A:input power voltage 100---AC100V(50/60Hz)
200---AC200V(50/60Hz)
220---AC220V(50/60Hz)
240---AC240V(50/60Hz)
B:Polarity N---Negative polarity(-)
P---Positive polarity(+)
C:Output terminal number 1---1 port
2---2 port
  20S (standard type): 35S3 (standard type):
Input AC100~240(50/60Hz) AC100、200、220、240V(50/60Hz)
Output DC polarity to be specified (either - or + polarity) DC polarity to be specified (either - or + polarity)
Output terminal 1 port. Output terminal for 20S. 1 port or 2 port (options)
Display Applied voltage display(kV) Over current display (mA) and applied voltage display (kV)
External output When power is not input, checking the over-current,
High-voltage occurs OFF:Close
High-voltage occurs:Open
1:Confirmed over current and output signal(NO)
2:Output high voltage (close in high voltage occuring)
Output current 0~500μA 0~2mA
Output voltage 0.1~20kV or-0.1~-20kV、continuously variable 0.1~35kV or-0.1~-35kV、continuously variable
Rectification Full-wave Full-wave
Method of insulation Dry Dry
Protection circuits (1)Over-current (2)Output short-circuit (1) Over-voltage (2)Over-current (3)Output short-circuit
Attachment Power cable 1.5m(2-Pin plug in)
metal consent for signal connecting (female)
Note:Doesn't include high voltage cable cord.
Power cable 2m
(input voltage with plug-in, open end type)
metal consent for signal connecting (female)
Note:Doesn't include high voltage power cable.