Shishido electrostatic, ltd., ESD solutions and productions.
Statiron DX multi function ESD field meter.
Static field meter.
This is a handy-size ESD Field meter, incorporating multiple functionalities including measurement of surface potential of ESD objects, monitoring of charged plate, and monitoring of ion balance. DX has a digital display and memory storage, and is capable of transferring data to external devices.
●With the minimum display unit of 1 V, it is most appropriate for use as part of the ESD.
●Incorporating a H.V. power supply unit and a timer, can demonstrate its monitoring functionality of ion balandevicece with charged plate and the atmosphere (when optional charged plate A or B is used). The minimum display unit at this time is 1 V.
●DX has the memory function to store sampling measurement and measurement data.
●By connecting the device to a PC, the data in DX can be transferred to the PC and be displayed in graph by using a spreadsheet software program.
●option : System Requirements of Data transmission software DX-tool : Japanese OS Only
Model | DX-01(Unit only) | DX-02(Set) |
---|---|---|
Signal detection method | Oscillating chopper ※1 | |
● Surface potential measurement ● | ||
Potential measurement range | Lo mode : 0~±1999V Hi mode : 0~±19.99kV |
|
Measurement accuracy | ±10% rdg ±2 digit Lo mode : 1V resolution Hi mode : 10V resolution |
|
Measurement distance | Lo mode : 30mm Hi mode : 50mm ( between measurement object and sensor) |
|
Measurement distance adjust | Red LED light focusing system adjustment (the light mark focusing distance is 30mm or 50mm) | |
Measurement object correction | standard : 200×200mm・50×50mm | |
Polarity display | Negative polarity( - ) only | |
Battery check | Amount of power remaining indicated on the display | |
● Attenuation measurement ※2 ● | ||
Alarm potential | - | Outside the -100 to + 100V / -10 to + 10V ranges |
Timer display | - | 0.0sec~900.0sec (Power off by timer) |
Potential display | - | 0V~±2000V |
● Ion balance measurement ※3 ● | ||
Alarm potential | - | Outside the -100 to + 100V / -10 to + 10V ranges |
Potential display | - | 0~±200V |
● Other functions ● | ||
Functions | Memory function for measured data Automatic power Off( after 15 minutes of non-activity) Automatic zero adjustment, analog output |
Memory function for measured data PC connection data managemen (t real time/memory mode) ※3 ※4 Automatic power Off( after 15 minutes of non-activity) Automatic zero adjustment, analog output |
Power supply | One 9 VDC alkaline battery for approximately 17 hours of continuous operation | |
Operating Environment | Temperature:0~40℃ Humidity:10~60%RH |
|
Main unit dimensions | 66×25×150mm(W×D×H) | |
Weight | 200g(included battery) | |
Accessories | AC adapter, 9VDC alkaline battery, grounding wire,cable for analog recorder, soft case for main unit |
AC adapter, 9VDC alkaline battery, grounding wire,cable for analog recorder, soft case for main unit, Charged plate A, charged plate B, cable for charged plate B, PC connection cable(RS-232C), PC connection software(DX-TOOL), stand, hard storage case for storing the options together with the main unit. |
Options for DX-01 |
Charged plate A, Charged plate B, cable for charged plate B, PC connection cable (RS-232C)、 PC connection software(DX-TOOL)、 stand、 hard storage case for storing the options together with the main unit. |
- |