Menu
Eliminostat DC-ESR-C
Shishido DC voltage bar type eliminostat DC-ESR-C.
The safety design uses only low-voltage wiring.

Shishido electrostatic, ltd., ESD solutions and productions.
Eliminostat DC-ESR-C bar type ionizer. DC voltage application method static eliminators.


●The DC-ESR-C is a bar ionizer that uses the corona discharge method to generate air ions. Air containing positive and negative ions effectively neutralizes the load on a charged object. With its low dust-emission design, this device is suitable for controlling ions in clean rooms and on clean benches. Since a small DC power supply is incorporated in the bar electrode, the device does not require a high-voltage cable. The safety design uses only low-voltage wiring, unlike other devices that require an external high-voltage power supply and high-voltage cables.
●Several units can be connected together by means of connectors provided at both ends of a device (up to 3 devices, provided up to 6 devices can be connected together by changing.

Adaptor for connected specification (optional)
1.To two electrodes at the connection : The AD-02 type.
2.To six electrodes at the connection : The AD-06 type.

 

Model DC-ESR-C
Input power supply DC24 V ±5 %
(Optional AC adapter supplied; compatible with 100~240 VAC)
Electric consumption 0.1A
Power source DC high voltage power source
Output voltage Min. DC4kV, Max. DC7kV
dimensions 32×50×(600・800・1000・1200・1400・1600・1800)mm
Weight 0.37kg (when L = 600mm)
Ion balance Adjustment function provided
Static decay time 2.1sec ※1
Amount of ozone generated 0.05ppm or less ※2
Material of Emitter Tungsten (can be changed to single-crystal silicon as an option)
Operating enviroment Ambient temperature:10~40℃
Ambient humidity 5~70%RH(no condensation)
Connect AC adapter(DA-02) : Max connect 2 set of eliminostat.
AC adapter(DA-06) : Max connect 6 set of eliminostat.
(The max extend length of cable cord : 12m)
Option AC adapter(DA-02,DA-06), Power cable(PWC-DC),
Electrode connecting cable(EC-DC500,EC-DC1500, EC-DC2500)
※1 Measured using a CPM measurement device (conforms to ESD.STM 3.1-2000) With the ion balance in a steady state,
  the static decay time is the time taken to decay from +1000 V to +100 V. Data obtained using the following parameters:
  Airflow: 0.3 m/sec, Distance: 300 mm.
※2 The ozone density was measured at a distance of 150 mm from the main unit's air outlet.