Menu
HDC-AC CABX
Shishido HDC-AC type ionizer CABX HDC-AC built-in bar type ionier. 30% improvement in static elimination times.

Shishido electrostatic, ltd., ESD solutions and productions.
Eliminostat CABX bar type ionizer. HDC-AC ionizer.


HDC-AC technology provides stable and long-term static elimination capabilities. We have designed an ionizer that does not require cleaning over the long term.

●30% improvement in static elimination times and product sizes (compared to Shishido Electrostatic’s existing products)
 The CABX is the next generation of Shishido Electrostatic’s existing CABC model. A 30% improvement over the existing product has been achieved with increased static elimination times and downsizing of the product. This is the industry’s leading static elimination ionizer.
●Simplified low-flow type emitter needle nozzle for air consumption
 Two types of emitter needle nozzles are available: the usual nozzle for air consumption and a low-flow type nozzle for compressed air consumption.
●Cleaning timer function that indicates the cleaning time
 An LED will light up when the timer had been set in advance and will indicate the cleaning time. The client can set the time when the light will appear. (9 patterns, 100-1000 hours and option not to set the light.)
●Emitter needle variations
 We provide needles that collect less dust, glass emitter needles and silicon emitter needles to respond to static elimination in environments in which little dirt is permitted.
●Maintaining safety
 Safety is maintained during use through the detection of minute electrical discharges and the low-voltage wiring input of the DC24V.
●Safety features detect abnormal discharges and sparks
 This safety feature automatically detects abnormal high-voltage discharge and shuts down the input such as when there is a short circuit in the ionizer's emitter needle.

●HDC-AC ionizers.
●Abnormal discharge alarm

 Detect the Abnormal discharge from the emitter and indicate with LED alarm.
●Over current alarm
 An LED indicator is provided to enable confirmation of over current of ionizer.
●Tungsten emitter needle
 Tungsten that was specially developed by our company is used in these emitter needles.
●Replaceable emitter needle
 Replaceable needle

●Product line-up: (length and weight details)

Model CABX
Used high voltage AC high voltage power(built-in)
Ion generation method Corona discharge method (HDC-AC)
Unit dimensions
(D×H×W)
29×92×350~3100mm
Input power supply DC24V ±5%
(Options: AC adapter)
Electric consumption 3.6VA
Output voltage ±10kV0-p(0 to peak)
Abnormal signal output Contact output under abnormal condition
(MOS FET Realay Normally close
Air tube connection
size
φ6(350mm~1600mm)、
φ8(1850mm~3100mm)、
Made of Nylon, soft nylon・Urethane
Air supply range 0.01~0.5MPa
Ion balance ±30V or less
(at distance 300mm, air pressure 0.3MPa)
Operating environment Surrounding temperature: 5 to 40 ℃ ,
surrounding humidity: 15% to 85% (no condensation)
Air supply: clean dry air
Accompanying items Operation manual, mounting bracket,
power supply and signal
connector cable (3 m),
intermediate bracket (over 1100 mm)