Shishido electrostatic, ltd., ESD solutions and productions.
Winstat BF-X2ZB-V2 DC system type static eliminator blower
High frequency type with cleaning check function.
●Safety louver
The easily attachable/detachable louver facilitates product maintenance. The safety mechanism ensures that operation stops automatically when the louver is removed.
●Airflow adjustment
The airflow can be adjusted.
●DC corona discharge system
The ionizer uses a DC corona discharge system.
●HV alarm output
An LED indicator and an alarm output signal are provided to enable confirmation of whether or not the high-voltage transformer is in the normal operating status.
●Cleaning Check [C.C] function
With detecting the abnormal discharge through the discharge emitter, it shows with C.C alarm LED.
●Tungsten emitter needle
Tungsten that was specially developed by our company is used in these emitter needles.
●Replaceable emitter needle
Replaceable needle
Model | BF-X2DD-V2 | ||||||
---|---|---|---|---|---|---|---|
Input power supply | DC24 V (with AC100 to 240 V AC adapter) | ||||||
Electric consumption | 15VA | ||||||
Output voltage | DC±7.5KV | ||||||
Ion balance | ±20Vor less (distance 300 mm; when shipped from the factory) |
||||||
Airflow | 1.7~3.6m3/min | ||||||
Air speed | 1.0~2.2m/sec(distance 300 mm; centered) | ||||||
Ozone density | 0.007ppm or less (distance 150 mm; centered) | ||||||
Operating Environment | 0 to 40℃ / 15 to 85% RH (no condensation) | ||||||
Filter | Non | ||||||
indicator | Green:POWER Yellow:Cleaning Check(C.C) Red:Power ALARM |
||||||
Output signal | NPN output High voltage(ALARM) Cleaning Check(C.C) |
||||||
Main unit dimensions | 150×182×62mm(W×H×D) not including protruding portion |
||||||
Weight | 900g(including stand) | ||||||
Noise level | 62dB(A)(distance 1m) | ||||||
Accompanying items | Operation manual, AC adapter, cleaning brush | ||||||
Optional parts | Discharge needle(4 pcs/pack): DN-W16 |