URYU
Controller & Tester
UTM Fastening counter
Uryu seisaku fastening counter with poka-yoke.
UTM-1500 informs you of error by display and buzzer when all bolts are not tightened up firmly.

This enables you to do "Pokayoke" for secure tightening.

UTM-1500(PS): Pressure Sensor Incorporated type
By connecting the TM signal hose from a tool to the coupler at the back of the controller, the pressure sensor incorporated in the controller converts the air pressure signal into the electric signal.

UTM-1500(CN): Connector Incorporated type
By connecting the pressure sensor (external pressure sensor assembly) attached to a tool to the connector at the back of controller, the controller supplies the power and loads the analog signal.

Features
• Applicable to the pneumatic tools such as the oil pulse wrenches, impact wrenches etc., or the electric tools, UDP-TA series. (Tool should be modified into the TM type because the controller basically detects the back pressure.)
• Counting down the fastening number, error proofing by the display and buzzer.
• Easy parameter setup the controller by front key switches followed to the front panel LCD. (It is possible to setup the parameters through a personal computer as well.) *TM convertible model : Various kinds of tools can be converted into TM type. Please ask your local URYU distributor for details.

Functions
• Easy setup for the pressure values by the automatic setup future.
• Up to 1500 tightening time and judging data points stored.
• Each buzzer volume level of fastening recognition, panel and NOK operation adjustable.
• Work select feature available for four different works with different numbers of fasteners.
• By equipping the external input/output terminal block (free format), inter lock with the line is possible.
• Parameters receivable/ transmittable, and wave data, memory data and the total numbers of fasteners receivable through PC.(Total numbers of pulse receivable in usage of the external pressure sensor assembly.)
• Measurement and display of the fastening time possible for the shut off tools.
• External pressure sensor assembly equipped for UTM-1500(CN) enables to count the pulse number so that the pulse number control becomes possible other than the fastening time control. (The pulse number cannot be detected sometimes depending on a tool or working conditions.)
• Total maintenance determined the total numbers of fasteners or pulse possible. (external pressure sensor assembly needed.)

Model Voltage & Frequency Operating ambient
temperature & humidity
Dimensions
mm
Weight
kg
UTM-1500A/E (PS) 115V / 230V
50Hz / 60Hz
0 - 50 degree (no freeze)
less 90%RH (no dewfall)
200 × 210 × 100 2.0
UTM-1500A/E (CN)
UTM-1500A/E (RA-PS) 280 × 220 × 420 6.4
UTM-1500A/E (RA-CN)

* TM convertible model : Various kinds of tools can be converted into TM type. Please ask us for details.