Features
・Low noise
・Low vibration
・Clean air and long life
・The world's first oil-free booster compressor
Applications
・Boosting of compressed air and nitrogen gas pressures
・Substitute for booster valves for energy saving
・Pressure boosting in case pressure is insufficient because of a decrease in air line pressure aimed at saving energy
Introduction Example:Hino Motors, Ltd.
(For Details:CSR website "CSR → Environmental Performance → Environmental Activities → CO2 Emissions Reduction at Production Plants")
2015/07/15 Added「movie」, please click the [movie] tag in above.
Lowering pressure for energy saving
Why not lower the supply pressure of the compressor?
While 60 to 70% of the equipment used in a manufacturing plant is designed to operate on low pressures, pressures as high as 0.7 MPa are typically supplied.
Lowering the supply pressure of the compressor can bring these energy-saving effects:
●Energy-saving effect ①
The power consumption of the compressor decreases.
●Energy-saving effect ②
The air consumption (including air leaks) decreases.
●Energy-saving effect ③
The load of the compressor decreases.
Lowering the supply pressure by 0.3 MPa
leads to an energy saving of about 20%!
CO2 emissions are cut by about 50 tons annually!
Three 37-kW compressors are used.
Operation time: 4,000 hours/year
Emission factor: 0.000555t-CO2/kWh
Calculated using the above conditions.
Introducing a booster to compensate for pressure insufficiency after lowering the pressure
Lower the pressure of the compressor
↓
Introduce a booster to compensate for pressure insufficiency
Features
The world's first oil-free type
The world's first oil-free compact booster compressor
The compressor can be installed easily even in narrow spaces where it was formerly difficult to install.
Low noise and low vibration
The closed-type compressor generates no valve noise. It is very quiet.
Long life
The compressor main unit requires intermediate maintenance at intervals of 10,000 hours.
A microcomputer board is included (EFBS15).
Pressure can be set arbitrarily.
Compact structure with an internal pressurizing mechanism (*) (EFBS04/07)
Compression loss is reduced to ease the motor load. No leak occurs during boosting.
Since the compressor can maintain gas purity, it is recommended for nitrogen gas boosting as well.
Model | Motor rated output Kw |
Control pressure MPa |
Air delivery ℓ/min |
Air tank ℓ |
Noise level dB(A) front 1.5m |
Dimensions mm (W x L x H) |
Mass kg |
EFBS04-9.5 | 0.4 | 0.8~0.95 | 220/270 (50Hz/60Hz) |
25 | 63/64 (50Hz/60Hz) |
530×285×625 | 28 |
EFBS07-9.5 | 0.75 | 0.8~0.95 | 370/430 (50Hz/60Hz) |
39 | 66/67 (50Hz/60Hz) |
775×330×660 | 45 |
EFBS15-10 | 1.5 | 0.85~1.0 | 600 | 55 | 68 | 855×475×760 | 80 |